| NO LEAKS ABSOLUTELY GUARANTEED The Logic Corporation can safely make that statement. The Logic Seal works below atmospheric pressure; air pressure outside the mold is always greater that the pressure in the molds water channels. The outside pressure will always force the coolant to flow in its channels. A leak is tamed before it can start. | ||||||||||||||||||||||||||||||||||||||||||||||
| With the Logic Sealtm leakstopper, faulty '0' rings
and cracks in the mold no longer mean an interruption in production: you just keep right
on molding! Often, you can
even achieve faster cycles due to improved coolant flow. The advantages don't stop there, however. As the owner of genuine Logic Corp. equipment, you may also be licensed, free of charge, to use any one of our exclusive, patented processes to decrease cycle time in truly dramatic fashion. These include Water Transfertm and Waterline Ventingtm. There are even many, many more techniques possible only with negative pressure technology. Logic Corp. offers free consultation to their customers in using any of these procedures. Talk to the professionals ... talk to Logic Corp. |
||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||
HOW TO SIZE UP A LOGIC SEAL TO A MOLD |
||||||||||||||||||||||||||||||||||||||||||||||
Please call 800-325-6442 to discuss your requirements or if you prefer, you can fill out the following & Fax it back to us at 866-395-1457. A representative will get back to you with the unit best suited for your application. |
||||||||||||||||||||||||||||||||||||||||||||||
| Guaranteed to stop the leak. | ||||||||||||||||||||||||||||||||||||||||||||||
| 1. Supply Pressure:___________________ 2. Drain Pressure:___________________ 3. G.P.M. required to the circuit the unit will operate:___________G.P.M. 4. If you do not know the G.P.M. |
||||||||||||||||||||||||||||||||||||||||||||||
| Give the following: | ||||||||||||||||||||||||||||||||||||||||||||||
| a. Dia. of cooling line into the mold circuit:_________Inches | ||||||||||||||||||||||||||||||||||||||||||||||
| b. Number of circuits _________ | ||||||||||||||||||||||||||||||||||||||||||||||
| 5. What phase do you prefer? | ||||||||||||||||||||||||||||||||||||||||||||||
| a. Single Phase 1) 110 volts 2) 240 volts | ||||||||||||||||||||||||||||||||||||||||||||||
| b. Three Phase 1) 240 volts 2) 480 volts ________ Phase | ||||||||||||||||||||||||||||||||||||||||||||||
| Voltage: ________ Volts | ||||||||||||||||||||||||||||||||||||||||||||||
| 6. Would you like temperature control of this circuit? Yes____ No____ | ||||||||||||||||||||||||||||||||||||||||||||||
| Customer information: | ||||||||||||||||||||||||||||||||||||||||||||||
| Company:_____________________________
Date:____________________
|
||||||||||||||||||||||||||||||||||||||||||||||
| Address:_______________________________________________________
|
||||||||||||||||||||||||||||||||||||||||||||||
| Contact
Name:____________________ Phone:______________________
|
||||||||||||||||||||||||||||||||||||||||||||||
| E-mail:___________________________ Fax:_________________________ | ||||||||||||||||||||||||||||||||||||||||||||||
Logic Seal Condensed Specifications
MODEL LS-100 Single phase
With a 4.7 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay, Thermal overload protection on motor, 110 volts (8 Amps)/240 volts (4 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switch for Low Supply pressure with indicator light, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 100 psi. All ports are 3/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 24 "W x 33"H
Weight: 120 lbs.
MODEL LS-100 Three phase
With a 4.7 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay (120 volt control circuit), Thermal and electronic overload protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts (3 Amps)/ 380-415 volts (1.8 Amps)/ 440-480 volts (1.5 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switch for Low Supply pressure with indicator light, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 100 psi. All ports are 3/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 24"W x 33"H
Weight: 120 lbs.
MODEL LS-300 Single phase
With a 14.6 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay, Thermal overload protection on motor, 110 volts (8 Amps)/ 240 volts (4 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switches for Low Supply & High Drain (return) pressures with indicator lights, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 40 psi. All ports are 3/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 24"W x 33"H
Weight: 120 lbs.
MODEL LS-300 Three phase
With a 14.6 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay (120 volt control circuit), Thermal and electronic overload protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts (3 Amps)/ 380-415 volts (1.8 Amps)/ 440-480 volts (1.5 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switches for Low Supply & High Drain (return) pressures with indicator lights, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 40 psi. All ports are 3/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 24"W x 33"H
Weight: 120 lbs.
MODEL LS-350 Three phase
With a 15.1 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay (120 volt control circuit), Thermal and electronic overload protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts (5.3 Amps)/ 380-415 volts (3 Amps)/ 440-480 volts (2.5 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switch for Low Supply pressure with indicator light, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 150 psi. All ports are 3/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 36"W x 34"H
Weight: 250 lbs.
MODEL LS-400 Three phase
With a 24 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay (120 volt control circuit), Thermal and electronic overload protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240volt(5.3 Amps)or 380-415volt(3 Amps)or 440-480volt(2.5 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switches for Low Supply & High Drain (return) pressures with indicator lights, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 40 psi.
All ports 1-1/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 24"W x 33"H
Weight: 120 lbs.
MODEL LS-500 Three phase
With a 52 gpm (max) positive displacement pump, circuit breaker on incoming power, motor starter relay (120 volt control circuit), Thermal and electronic overload protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts (6.4 Amps)/ 380-415 volts (3.5 Amps)/ 440-480 volts (3 Amps)50/60 Cycle, UL/CE Rated, Safety shut off switches for Low Supply & High Drain (return) pressures with indicator lights, vented steel cabinet, bonded rubber casters, liquid filled compound gauges on TO MOLD and FROM MOLD lines, liquid filled SUPPLY and RETURN pressure gauges, adjustable bronze pressure regulating valve, bronze inline filter, adjustable flow control circuit to minimize part wear, copper and bronze plumbing, max. drain (return) pressure capability is 40 psi. All ports are 1 1/4" NPT (TO MOLD, FROM MOLD, SUPPLY & DRAIN (Return)
Size: 14"L x 36"W x 34"H
Weight: 250 lbs.