CONDENSED EQUIPMENT SPECIFICATIONS
MODEL VT-1800 H C (NO Heater)
- 37 gpm, Closed-loop Negative Pressure System, .75 HP Pump
- Digital Dual Readout Temperature Controller
- Circuit Breaker on Incoming Power
- Motor Starter Relay
- Electronic Overload Protection on Motor
- Pump Reversal Protection with Indicator Light (Phase Monitor)
- Avail.Voltages: 208-240/8 Amps,460-480/4 Amps,(120 volt control circuit)
- All Electrical Components are UL/CE Rated
- Pre-vac Switch(to prevent unwanted pressure to the mold before start-up)
- Liquid Filled Gauges: TO MOLD, FROM MOLD, COOLING SUPPLY, AIR SUPPLY
- Copper and Bronze Plumbing
- An estimated 4 Gallon Stainless Steel Reservoir Tank
- Automatic Filling (filling and maintaining fluid level)
- Logic’s Air Separation & Removal System with Indicator Lights
- 3.2 Sq. Ft. Heat Exchanger
- Powder Coated, Ventilated Steel Cabinet
- Bonded Rubber Casters
- Post sizes: 1-1/4” NPT: TO MOLD, 1” NPT: FROM MOLD,
3/4” NPT: AIR, RESERVOIR and COOLING and COOLING RETURN
CABINET: L:14" W:24" H:33" WEIGHT: 180 lbs.
Approximate Ship Weight 210 lbs
Approximate Ship Size: 25"L x 40"W x 37"H
Ships: Class 85, Common Carrier
H.S.Code: 8479.80.000
Specifications subject to change without notice. "Vac-U-Temp" is a trademark of Logic Corporation. Vac-U-Temp temperature controller/leakstopper U.S.Patent #4,287,941.
|