Vac-U-Temptm |
Nothing out performs |
|
||||||||||||||||||||||||||||||||||||||||||
|
PROVIDES MOLDERS WITH DESIGN FLEXIBILITY AND FASTER CYCLES |
||||||||||||||||||||||||||||||||||||||||||
|
Takes advantage of negative pressure (whether using water, ethylene glycol, or hot oil). Hot oil under negative pressure - up to 400 degrees. Little or no pressure in your cooling line minimizes dangerous burns from hot oil. Capable of controlling mold temperature = or - 1 degree fahrenheit. |
||||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONS |
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||
| Electrical requirement: 208-240 380, 440-480
volt. 3 phase 60 hertz. With 120 volt control circuit. All units include the following: Heavy duty ventilated steel cabinet / bonded rubber casters / easy access to operating controls / complete with vacuum transducers, vacuum adjustment switches and gauges TO MOLD, FROM MOLD, Cooling and Air Supply gauges / copper and bronze plumbing / approx. 5 U.S. gallon stainless steel reservoir vessel / automatic fill control / air separation and removal system / Cooling coil or Heat Exchanger / low watt density heaters / fused incoming power
|
Vac-U-Temp Condensed Specifications
MODEL VT-1800
A closed-loop, negative pressure system, with 22 gpm capability. 3/4 hp motor, digital dual readout temperature controller. Easy access to operating controls. Circuit breaker on incoming power, motor starter relay (120 volt control circuit), Electronic Overload Protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts/ 8 amps, or 480 volts/4 amps 50/60 Cycle, UL/CE Rated, Complete with vacuum Venturi and vacuum switch (Unit is equipped with a "Pre-Vac" switch to allow the system to be placed under a vacuum and prevent unwanted pressure to the mold before start-up. "Pre-Vac" may also be used for first time reservoir fill if unit has optional separate fill port, so that the correct amount of fluid is available at start-up.) TO MOLD, FROM MOLD, COOLING SUPPLY and AIR SUPPLY liquid filled gauges. Copper and bronze plumbing, 4.00 (approx) gallon stainless steel reservoir vessel with automatic filling. Logic’s Air Separation and Removal System with indicator lights. Equipped with a 3.2 square foot Heat Exchanger. 6 Kw low watt density heaters for a maximum temperature of 260 degrees F, using pure industrial ethylene glycol under negative or positive pressure, 210 degrees F using water under positive pressure, or 180 degrees F using water under negative pressure. (Max Temperature will vary depending on pressure using water.) Heavy duty ventilated steel cabinet, bonded rubber casters.
PORT SIZES: (all female NPT) 3/4" TO MOLD &
1" FROM
MOLD
3/4" Coolant Supply, Return, Air Inlet, & Reservoir Supply.
CABINET: L:14" W:24" H:33" WEIGHT: 180 lbs.
MODEL VT-2600
A closed-loop, negative pressure system, 50 gpm capability. 1.5 hp motor. Digital dual readout temperature controller. Easy access to operating controls. Circuit breaker on incoming power, motor starter relay (120 volt control circuit), Electronic Overload Protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts /13.2 Amps or 440-480 volts /8.2 Amps. 50/60 Cycle, UL/CE Rated, Complete with vacuum transducers and vacuum switch (Unit is equipped with a "Pre-Vac" switch to allow the system to be placed under a vacuum and prevent unwanted pressure to the mold before start-up. "Pre-Vac" is also used for first time reservoir fill so that the correct amount of fluid is available at start-up.) TO MOLD, FROM MOLD, COOLING SUPPLY and AIR SUPPLY liquid filled gauges. Copper and bronze plumbing, 5.27(approx) U.S. gallon stainless steel reservoir vessel with automatic filling. Logic’s Air Separation and Removal System with indicator lights. Equipped with a 3.2 square foot Heat Exchanger. 6 Kw low watt density heaters for a maximum temperature of 260 degrees F, using pure industrial ethylene glycol under negative or positive pressure, 210 degrees F using water under positive pressure, or 180 degrees F using water under negative pressure. (Max Temperature will vary depending on pressure using water.) Heavy duty ventilated steel cabinet, bonded rubber casters.
PORT SIZES: (all female NPT) 1-1/4" TO MOLD & FROM
MOLD
3/4" Coolant Supply, Return, Air Inlet, & Reservoir Supply.
CABINET: L:36" W:14" H:33" WEIGHT: 210 lbs.
MODEL VT-3000
A closed-loop, negative pressure system, with 50 gpm capability. 1.5 hp motor. Digital dual readout temperature controller. Easy access to operating controls. Circuit breaker on incoming power, motor starter relay (120 volt control circuit), Electronic Overload Protection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts /13.2 Amps or 440-480 volts /8.2 Amps. 50/60 Cycle, UL/CE Rated, Complete with vacuum transducers and vacuum switch (Unit is equipped with a "Pre-Vac" switch to allow the system to be placed under a vacuum and prevent unwanted pressure to the mold before start-up. "Pre-Vac" is also used for first time reservoir fill so that the correct amount of fluid is available at start-up.) TO MOLD, FROM MOLD, COOLING SUPPLY and AIR SUPPLY liquid filled gauges. Copper and bronze plumbing, 5.27(approx) U.S. gallon stainless steel reservoir vessel with automatic filling and Logic’s Air Separation and Removal System with indicator lights. Equipped with a 2.6 square foot heat exchanger. (The unit uses a constant flow of coolant supply to maintain a cold fluid reserve in the heat exchanger, while the heater tank temperature is maintained at set-point. After initial warm-up, the circuit switches between the two as needed, sending the correct fluid temperature to the mold instantly.) Low watt density heaters for a maximum temperature of 300 degrees F, (using approved transfer fluid under negative pressure.) Heavy duty ventilated steel cabinet, bonded rubber casters.
PORT SIZES (all female NPT): 1-1/4" TO MOLD & FROM MOLD:
3/4" Coolant Supply, Return, Air Inlet & Reservoir Fluid
CABINET: L: 14" W: 36" H: 33" WEIGHT: 210 lbs.
MODEL VT-4000
A closed-loop, negative pressure system, with 50 gpm capability. 1.5 hp motor. Digital dual readout temperature controller. Easy access to operating controls. Circuit breaker on incoming power, motor starter relay (120 volt control circuit), Electronic Overload Pprotection on motor, pump reversal protection with indicator light (Phase Monitor), 208-240 volts /28.2 Amps or 440-480 volts /16.1 Amps. 60 Cycle, UL/CE Rated, Complete with vacuum transducers, vacuum switch, Pre-vac switch (allowing the system to be placed under a vacuum and prevent unwanted pressure to the mold before start-up. Pre-Vac is also used for first time reservoir fill so that the correct amount of fluid is available at start-up.) and an Air Mold Purge Valve (which reduces fluid loss by removing all fluids from mold and hoses before hoses are removed.) TO MOLD, FROM MOLD, COOLING SUPPLY and AIR SUPPLY liquid filled gauges. Stainless steel and bronze plumbing, 5.27(approx) U.S. gallon stainless steel reservoir vessel with automatic filling and Logic’s Air Separation and Removal System with indicator lights. Equipped with a 4.6 square foot heat exchanger. (The unit uses a constant flow of coolant supply to maintain a cold fluid reserve in the heat exchanger, while the heater tank temperature is maintained at set-point. After initial warm-up, the circuit switches between the two as needed, sending the correct fluid temperature to the mold instantly.) Low watt density heaters for a maximum temperature of 400 degrees F, (using approved transfer fluid under negative pressure.) Heavy duty ventilated steel cabinet, bonded rubber casters.
PORT SIZES (all female NPT):1-1/4" TO MOLD & FROM MOLD:
3/4" Coolant Supply, Return, Air Inlet & Reservoir Fluid
CABINET: L: 14" W: 36" H: 33" WEIGHT: 250 lbs.
Vac-U-Temp Options
VT OPT-15- 4000
(All models)
Emergency Stop Switch
VT
OPT-16- 2600 (All
models)
Built-in SS Basket Strainer
VT
OPT-17
Timer 110 volt used for
water transfer
VT
OPT-18
Flow Safety Switch
VT
OPT-19
Hi/Low Audible Alarm
VT
OPT-2H
(VT-2600 & 3000)
Additional Heater: Double
the KW output by number of heaters used
VT
OPT-3-26/30 (Standard
on VT-4000)
Air Mold Purge Valve: Used
to remove all fluids from mold and hoses before the hoses are removed.
Saves time and money by reducing fluid loss.
VT
OPT-35-3000 (Standard
on VT-4000)
Outside Auxiliary Tank:
Excess purged liquids. Capacity 3 Gallons
VT
OPT- 4 (All models)
Safety Vacuum Signal
VT
OPT-6- 2600 (VT-2600
only)
2.6 Heat Exchanger: Add internal heat exchanger to increase cooling capacity
from 1.5 square
feet to 2.6 square feet
VT
OPT-6
3.7 Heat Exchanger: Internal, Provides 3.7 square feet of cooling.
VT
OPT-6A (VT-2600 &
3000)
4.6 Heat Exchanger:
External, provides 4.6 square feet of cooling
VT
OPT-10-2600
Mold Circuit flow meter with Digital display
VT
OPT-36- 1800 (VT-1800
only)
Separate Fill Port - separates fill & cooling fluid, allowing use of HTF, EG or
distilled water
Some options listed reference
a specific model number, although they might also be used in another model
number.
| [ Home ] [ About Us ] [ Products ] [ Consulting ] [ Representatives ] |
Copyright 1998,1999 Logic Corp. All rights reserved. Click for detailed Copyright information. Last changed 05/28/08